Comparison of Coatings Specifications

Test Parameter

AAMA 2603

AAMA 2604

AAMA 2605 and ASCA 96

PRETREATMENT REQUIREMENTS

Metal Preparation and Pretreatment

Multi-stage cleaning and pretreatmentMulti-stage cleaning and pretreatmentMulti-stage cleaning and pretreatment
Pretreatment TypeChemical conversion coatingChrome or non-chrome chemical conversion coatingAmorphous chromium phosphate or amorphous chromate treatment
Pretreatment Coating Weightnone specifiedChrome=30 mg/ft? minimum; non-chrome per supplier’s specificationChrome=40 mg/ft? minimum
PAINT FILM REQUIREMENTS
Dry Film Thickness0.8 mils minimum1.2 mils (for multicoat, 1.0 mil topcoat minimum & 0.3 +/- 0.1 mil primer)

1.2 mils (for multicoat, 1.0 mil topcoat minimum & 0.3 +/- 0.1 mil primer)

(None specified under ASCA 96)

Sealant Compatibilitymeets AAMA 800meets AAMA 800meets AAMA 800

Specular Gloss

+/- 5 units of specification (high=80+, medium=20-79, low?19)

+/- 5 units of specification (high=80+, medium=20-79, low?19)+/- 5 units of specification (high=80+, medium=20-79, low?19)
Dry Film HardnessH minimumF minimumF minimum

ADHESION REQUIREMENTS

Dry Adhesion0% failure (no loss)0% failure (no loss)0% failure (no loss)
Wet Adhesion0% failure (no loss)0% failure (no loss)0% failure (no loss)
Boiling Water Adhesionnone specified0% failure (no loss)0% failure (no loss)
Impact Resistanceno removal of film from substrateno removal of film from substrateno removal of film from substrate
Abrasion Resistancenone specifiedabrasion coefficient value = 20 minimumabrasion coefficient value = 40 minimum
CHEMICAL RESISTANCE REQUIREMENTS
Muriatic Resistance15-minute exposure: no blistering or visual change15-minute exposure: no blistering or visual change15-minute exposure: no blistering or visual change
Mortar Resistance24-hour exposure: no loss of film adhesion or visual change24-hour exposure: no loss of film adhesion or visual change24-hour exposure: no loss of film adhesion or visual change
Nitric Acid Resistancenone specified30-minute exposure: 5 Delta E (Hunter) maximum color change30-minute exposure: 5 Delta E (Hunter) maximum color change
Detergent Resistance72-hour exposure: no loss of adhesion, no blistering, no significant visual change72-hour exposure: no loss of adhesion, no blistering, no significant visual change72-hour exposure: no loss of adhesion, no blistering, no significant visual change
Window Cleaner Resistancenone specified24-hour exposure: no blistering or appearance change

24-hour exposure: no blistering or appearance change

(None specified under ASCA 96)

 CORROSION RESISTANCE REQUIREMENTS

Humidity Resistance1,500 hours: no more than “few” blisters size 8, figure no. 4, ASTM D 7143,000 hours: no more than “few” blisters size 8, figure no. 4, ASTM D 7144,000 hours: no more than “few” blisters size 8, figure no. 4, ASTM D 714
Salt Spray Resistance

1,500 hours of salt solution: minimum rating of 7 on scribe or cut edges; minimum blister rating of 8 in the field

(ASTM D 1654)

3,000 hours of salt solution: minimum rating of 7 on scribe or cut edges; minimum blister rating of 8 in the field

(ASTM D 1654)

4,000 hours of salt solution: minimum rating of 7 on scribe or cut edges; minimum blister rating of 8 in the field

(ASTM D 1654)

WEATHERING RESISTANCE REQUIREMENTS
Accelerated Exposure1,000 hours in Atlas Type “XW” weatherometer: no adhesion loss; slight chalking or color changenone specifiednone specified
Outdoor Exposure1 year South Florida, 45m south: no adhesion loss; slight chalking or fading

5 years South Florida, 45m south: 5 Delta E (Hunter) maximum color change; chalking < 8 (ASTM

D 4214); gloss retention > 30%; erosion resistance < 10% film loss

10 years South Florida, 45m south:

 5 Delta E (Hunter) maximum color change; chalking < 8 (ASTM

D 4214), gloss retention > 50%; erosion resistance < 10% film loss

This table is a cursory comparison of some of the common elements of the referenced specifications.  Far greater detail can be found in the specifications themselves.  For copies of the specifications, please contact American Architectural Manufacturers Assocation.